Inverted siphons shall have not less than two barrels, with a minimum pipe size of 6 inches (150 mm).  They shall be provided with necessary appurtenances for maintenance, convenient flushing, and cleaning equipment.  The inlet and discharge structures shall have adequate clearances for cleaning equipment, inspection, and flushing.  Design shall provide sufficient head and appropriate pipe sizes to secure velocities of at least 3.0 feet per second (0.9 m/s) for design average flows.  The inlet and outlet details shall be so arranged that the design average flow is diverted to one barrel, and so that either barrel may be cut out of service for cleaning.  The vertical alignment should permit cleaning and maintenance.